SuperTrak66™ User's Manual

Chapter 5

The fields displayed on the previous page are defined as follows:

Name

This field contains the name of the array.

RAID Level

The “RAID level” text box contains the RAID level information of the array. Pressing on the arrow along on the right edge of the text box (operational only when creating a new array) displays a list of choices (RAID levels 0, 1, 3, 5, or spanning).

Block Size (KB)

The “Block size” reflects the stripe block size information used by this array. This value cannot be modified here.

Cache Policy Settings

The “Cache policy settings” section contains several fields related to the caching mode of the array as follows:

Read cache

This field shows the current read cache setting. The options are “ON” and ”Cache OFF.” “OFF” disables the entire caching system, including write caching.

Write cache

This is the write cache mode. Pressing on the arrow on the right edge of the text box displays a list of choices: “Off” (turns off write and write back caching); “write back” (enables the write and write back caching).

NOTE: Flush parameters of write and write back caching are set in the IOPX Information View; see p. 84 for more information. Read Ahead mode and Range settings are not available in this version.

Cache statistics

The cache stat istics are displayed, but cannot be modified from here.

Read cache hit

This field shows the number of read cache requests made to this particular array since the field was last reset.

Write cache hit

This field shows the number of write cache requests made to this particular array since the field was last reset.

- 99 -

Page 110
Image 110
Promise Technology 66 Pro user manual Name, Block Size KB, Cache Policy Settings, Read cache, Write cache, Cache statistics