Fluke 5725A instruction manual A5 Digital PCA

Models: 5725A

1 196
Download 196 pages 44.16 Kb
Page 154
Image 154

5725A

Instruction Manual

Table 8-6. A5 Digital PCA

Reference

Description

Designator

Fluke Stock

No

Tot Qty

Notes

C501,C503-511, C516,C518,C519, C521 C502,C520 C512,C513 C514,C517 C515

C522-530

C531

CR501,CR504,

CR505

CR502,CR506,

CR507

CR508,CR509

E501

J501

J502

J504

J506-509

J512,J515

L501

MP501

MP815

R501

R502,R509

R503-507

R508

R510

SW502

TP501-510

U501,U510

U502

U503

U504

U505

U506

U507

U508

U509

U511,U514

U512

U513

U515

Y501

Z501

Z502

CAP,POLYES,0.1UF,+-10%,50V

CAP,AL,22UF,+-20%,35V

CAP,CER,15PF,+-20%,50V,C0G

CAP,POLYES,0.33UF,+-10%,50V

CAP,TA,10UF,+-20%,35V

CAP,CER,470PF,+-5%,50V,C0G

CAP,CER,100PF,+-5%,50V,C0G

LED,GREEN,LIGHT BAR,5.0 MCD

LED,RED,LIGHT BAR,6.0 MCD

*DIODE,SI,SCHOTTKY,40V,DO-34 HEADER,1 ROW,.100CTR,4 PIN SOCKET,IC,0.070 CTR,64 PIN HEADER,2 ROW,.100CTR,RT ANG,34 SOCKET,IC,28 PIN

SOCKET,IC,8 PIN SOCKET,IC,24 PIN CHOKE, 3 TURN PAD, ADHESIVE

CABLE, INTERCONNECT - FRONT PA RES,MF,1M,+-1%,0.125W,100PPM RES,CF,1K,+-5%,0.25W RES,CF,47K,+-5%,0.25W RES,MF,11.5,+-1%,0.125W,100PPM RES,CF,10K,+-5%,0.25W

SWITCH,PUSHBUTTON,SPST,MOMENTA

JUMPER,WIRE,NONINSUL,0.200CTR

*IC,CMOS,OCTAL D TRANSPARENT LA

*IC,CMOS,HEX INVERTERS

*IC,CMOS,OCTL LINE DRVR W/3-ST

*IC, 2K X 8 STAT RAM

*IC,CMOS,QUAD INPUT NOR GATE

*IC,CMOS,14 STAGE BINARY COUNTE

*IC,CMOS,8-BIT MPU,2.0 MHZ,256

*IC,VOLT SUPERVISOR,4.55V SENSE

*IC,CMOS,DUAL MONOSTABLE MULTIB

*IC,CMOS,QUAD 2 INPUT NAND GATE IC, NMOS, 2K X 8 EEPROM, 350 N

*IL,CMOS,QUAD 2 INPUT AND GATE

*EPROM,PROGRAMED 27128A-150 U51 CRYSTAL,4.9152 MHZ,+/- 0.005%, RES,CERM,DIP,16 PIN,15 RES,10K RES,CERM,DIP,16 PIN,8 RES,24,+

649913

649913

649913

817056

697524

715284

816512

830430

831495

845136

845136

534834

534834

313247

417329

783688

836551

448217

478016

376236

452888

735365

843123

268797

343426

348896

339796

348839

782656

816090

743294

799924

741892

647222

811158

807701

876326

780577

454017

707323

811075

741801

860148

800367

355305

806406

14

2

2

2

1

9

1

3

3

2

1

1

1

1

4

2

1

1

1

1

2

5

1

1

1

10

2

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

8-28

Page 154
Image 154
Fluke 5725A instruction manual A5 Digital PCA

5725A specifications

The Fluke 5725A is a high-performance, multifunctional temperature calibration source designed to meet the demanding requirements of laboratory and industrial environments. Renowned for its accuracy, reliability, and versatility, the 5725A serves as a powerful tool for engineers and technicians engaged in temperature calibration processes.

At the core of the 5725A is its advanced measurement technology, which allows for precision temperature calibrations across a wide range. With an operating temperature range from -200°C to 660°C, it caters to various applications, making it suitable for calibrating thermocouples, resistance temperature detectors (RTDs), and other temperature measurement devices.

One of the standout features of the Fluke 5725A is its outstanding accuracy, boasting a specified uncertainty of just ±0.15°C. This level of precision ensures that users can maintain compliance with regulatory standards and regulatory requirements in fields such as aerospace, pharmaceuticals, and manufacturing.

The Fluke 5725A is equipped with dual-channel capabilities, allowing users to calibrate two devices simultaneously. This enhances productivity by minimizing downtime and optimizing workflow efficiency. The intuitive touchscreen interface simplifies operations, enabling users to view measurements, set up test parameters, and access historical data with ease.

Versatile connectivity options such as USB and Ethernet enable seamless integration into existing systems and allow for data transfer, remote control, and configuration. This feature empowers technicians to conduct calibrations efficiently, whether on-site or remotely.

The robust design of the Fluke 5725A ensures its durability in demanding environments. Built with high-quality materials, it is resistant to shocks and vibrations, making it suitable for use in manufacturing plants and laboratories where equipment may be subjected to harsh conditions.

Another notable characteristic of the 5725A is its ability to generate stable temperature outputs with minimal drift, contributing to consistency in calibration results. Its built-in self-test functionality helps ensure that the unit remains in peak operating condition, giving users confidence in their calibration processes.

In summary, the Fluke 5725A is a top-tier temperature calibration source that excels in accuracy, reliability, and user-friendliness. Whether in laboratory settings or industrial applications, its advanced technologies and features make it an essential tool for professionals tasked with maintaining precision in temperature measurements.