Fluke 5725A Introduction and Specifications, Resistance Nominal Value, Hours, Days, Year, ±ppm

Models: 5725A

1 196
Download 196 pages 44.16 Kb
Page 27
Image 27
Resistance

Introduction and Specifications 1

Specifications

Resistance

Nominal

Value

Ω

Absolute Uncertainty of Characterized Value

±5°C from calibration temperature [Note 1]

 

24 Hours

 

90 Days

 

180 Days

 

1 Year

 

 

 

 

±ppm

 

 

 

 

 

 

 

 

 

 

 

 

Relative Uncertainty

±1°C

 

24 Hours

 

 

90 Days

 

 

±ppm

 

 

 

 

 

 

 

 

0

1

1.9

10

19

100

190

1k

1.9k

10k

19k

100k

190k

1M

1.9M

10M

19M

100M

50μΩ

85

85

26

24

15

15

11

11

9

9

11

11

16

17

33

43

110

50μΩ

95

95

28

26

17

17

12

12

11

11

13

13

18

19

37

47

120

50μΩ

100

100

30

28

18

18

13

13

12

12

14

14

20

21

40

50

125

50μΩ

110

110

33

31

20

20

15

15

14

14

16

16

23

24

46

55

130

50 μΩ

50 μΩ

32

40

25

33

5

8

4

7

2

4

2

4

2

3.5

2

3.5

2

3.5

2

3.5

2

3.5

2

3.5

2.55

3.56

10

14

20

24

50

60

Secondary Performance Specifications and Operating Characteristics

Included in Uncertainty Specifications

Nominal

Value

Ω

0

1

1.9

10

19

100

190

1k

1.9k

10k

19k

100k

190k

1M

1.9M

10M

19M

100M

Notes:

 

Temperature

 

Coefficient

Stability

[Note 2]

 

 

 

±1°C

 

 

0°-10°C

24 Hours

10°-40°C

 

and

 

 

 

40°-50°C

 

 

 

 

 

 

 

±ppm

±ppm/°C

 

32

 

 

 

4

 

5

25

6

 

7

5

 

 

2

 

3

4

2

 

3

2

2

 

3

2

2

 

3

2

2

 

3

2

2

 

3

2

2

 

3

2

2

 

3

2

 

 

2

 

3

2

2

 

3

2.5

2.5

 

6

3.5

3

 

10

10

5

 

20

20

8

 

40

50

12

 

100

Full

Spec

Load

Range

[Note 3]

mA

8-500

8-100

8-100

8-11

8-11

8-11

8-11

1-2

1-1.5

100-500 μA

50-250 μA

10-100 μA

5-50 μA

5-20 μA

2.5-10 μA

.5-2 μA

.25-1 μA

50-200 nA

Maximum

Peak

Current

mA

500

700

500

220

160

70

50

22

16

7

5

1

500μA

100μA 50 μA

10μA 5 μA 1 μA

Maximum

Difference

of

Characterized

to Nominal

Value

±ppm

500

500

300

300

150

150

150

150

150

150

150

150

200

200

300

300

500

Two-Wire Adder active compensation [Note 4]

Lead

Resistance

0.1Ω

 

 

 

1Ω

 

±mΩ

2

 

 

 

4

2

 

4

2

 

 

4

2

 

 

4

2

 

 

 

4

2

 

 

 

4

2

 

 

4

10

 

 

15

10

 

 

 

15

 

 

 

 

 

5060

100 120

1.Specifications apply to displayed value. 4-wire connections, except 100 mΩ.

2.Temperature coefficient is an adder to uncertainty specifications that does not apply unless operated more than 5°C from calibration temperature, or calibrated outside the range 19°C to 24°C. Two examples:

a)Calibrate at 20°C: Temperature coefficient adder is not required unless operated below 15°C or above 25°C.

b)Calibrate at 26°C: Add 2°C temperature coefficient adder. Additional temperature coefficient adder is not required unless o perated below 21°C or above 31°C.

3.Refer to current derating factors table for loads outside of this range.

4.Active two-wire compensation may be selected for values less than 100 kΩ, with either the front panel or the meter input terminals as reference plane. Active compensation is limited to 11 mA load, and to 2V burden. Two wire compensation can be used only with Ω meters that

source continuous (not pulsed) dc current.

1-11

Page 27
Image 27
Fluke 5725A Introduction and Specifications, Resistance Nominal Value, Absolute Uncertainty of Characterized Value, Hours