Memory Map/Register Definition
MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2
Freescale Semiconductor 11-3

11.2.1.1 RTC Hours and Minutes Counter Register (HOURMIN)

The real-time clock hours and minutes counter register (HOURMIN) is used to program the hours and

minutes for the TO D clock. It can be read or written at any time. After a write, the time chan ges to the new

value. A power-on reset (POR) sets the RTC to the reset values shown in Figure 11-2.

Figure 11-2. RTC Hours and Minutes Counter Register (HOURMIN)

IPSBAR
Offset: 0x03C0 (HOURMIN)
Access: User read/write
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
R 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset1
1After power-on reset (POR)
0000000000000000
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
R 0 0 0 HOURS 0 0 MINUTES
W
Reset1000?????00??????

Table 11-2. HOURMIN Field Descriptions

Field Description
31–13 Reserved, should be cleared.
12–8
HOURS
Hour setting; can be set to any value between 0 and 23.
7–6 Reserved, should be cleared.
5–0
MINUTES
Minutes setting; can be set to any value between 0 and 59.