Memory Map/Register Definition
MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2
Freescale Semiconductor 11-11

11.2.1.9 RTC Days Counter Register (DAYS)

The real-time clock days counter register (DAYS) is used to program the day for the TOD clock. When the

HOUR field of the HOURMIN register rolls over from 23 to 00, the day counter increments. It can be read

or written at any time. After a write, the time changes to the new value. This register cannot be reset

because the real-time clock is always enabled at reset. Only 16-bit accesses to this register are allowed.

Figure 11-10. RTC Days Counter Register (DAYS)

IPSBAR
Offset: 0x03E0 (DAYS)
Access: User read/write
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
R 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset0000000000000000
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RDAYS
W
Reset????????????????

Table 11-10. DAYS Field Descriptions

Field Description
31–16 Reserved, should be cleared.
15–0
DAYS
Day Setting. This field indicates the current day count, and can be set to any value between 0 and 65535.