Real-Time Clock
MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2
11-4 Freescale Semiconductor

11.2.1.2 RTC Seconds Counter Register (SECONDS)

The real-time clock seconds register (SECONDS) is used to program the seconds for the TOD clock. It

can be read or written at any time. After a write, the time changes to the new value. A power-on reset

(POR) sets the RTC to the reset values shown in Figure 11-3.

Figure 11-3. RTC Seconds Counter Register (SECONDS)

IPSBAR
Offset: 0x03C4 (SECONDS)
Access: User read/write
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
R 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset1
1After power-on reset (POR)
0000000000000000
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
R0000000000SECONDS
W
Reset0000000000??????

Table 11-3. SECONDS Field Descriptions

Field Description
31–6 Reserved, should be cleared.
5–0
SECONDS
Seconds setting; can be set to any value between 0 and 59.