Debug Module
MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2
Freescale Semiconductor 28-5

28.3.1 Begin Execution of Taken Branch (PST = 0x5)

PST is 0x5 when a taken branch is executed. For some opcodes, a branch tar get address may be displayed
on DDATA depending on the CSR settings. CSR also controls the number of address bytes displayed,
which is indicated by the PST marker value immediately preceding the DDAT A nibble that begins the data
output.
Multiple byte DDATA values are displayed in least-to-most-significant order . The processor captures only
those target addresses associated with taken branches which use a variant addressing mode, or RTE and
RTS instructions, JMP and JSR instructions using address register indirect or indexed addressing modes,
and all exception vectors.
The simplest example of a branch instruction using a variant address is the compiled code for a C language
case statement. Typically, the evaluation of this statement uses the variable of an expression as an index
into a table of offsets, where each offset points to a unique case within the structure. For such
change-of-flow operations, the ColdFire processor uses the debug pins to output the following sequence
of information on two successive processor clock cycles:
1. Use PST (0x5) to identify that a taken branch is executed.
2. Using the PST pins, optionally signal the target address to be displayed sequentially on the DDATA
pins. Encodings 0x9–0xB identify the number of bytes displayed.
3. The new target address is optionally available on subsequent cycles using the DDATA port. The
number of bytes of the target addr ess displayed on this port is configurable (2, 3, or 4 bytes, where
the encoding is 0x9, 0xA, and 0xB, respectively).
Another example of a variant branch instruction would be a JMP (A0) instruction. Figure 28-2 shows the
PST and DDATA outputs that indicate a JMP (A0) execution, assuming the CSR was programmed to
display the lower 2 bytes of an address.
Figure 28-2. Example JMP Instruction Output on PST/DDATA
PST of 0x5 indicates a taken branch and the marker value 0x9 indicates a 2-byte address. Therefore, the
subsequent 4 nibbles of DDATA display the lower two bytes of address register A0 in
least-to-most-significant nibble order . The PST outpu t after the JMP instruction completes depends on the
target instruction. The PST can continue with the next instruction before the address has completely
displayed on DDAT A because of the DDATA FIFO. If the FIFO is full and the next instruction has captured
values to display on DDATA, the pipeline stalls (PST = 0x0) until space is available in the FIFO.
DDATA
PSTCLK
0x0 0x0 A[3:0]
0x5 0x9 default
PST
A[7:4] A[11:8] A[15:12]
default default default