Installation
Making Cable Connections
2–15MMDS0508 Target Interface
If you need the second logic cable assembly, connect it in the same way to the
remaining pod connector of the station module. Make target-system connections as for
the first cable.
2.5.3 Target Cable Connection
To connect the MMDS to a target system, you must use a target cable assembly: a
target cable and a target head.
NOTE Press only on the rigid plastic terminators of the cable. Pressing on
the flexible part of the cable can damage the cable.
Follow these instructions:
1. Make sure that station module power is off; make sure that power is not applied to the
target system.
2. Remove the MMDS access panel, for access to the EM.
3. The EM has one or two target connectors, on its right side. Connect the target cable’s
emulator terminal to the EM target connectors.
4. Connect the target cable’s head terminator to the appropriate target head adapter.
NOTE The EM user’s manual should identify the target head adapter
appropriate for your target system. Make sure that the adapter and the
target cable mate correctly.
5. Plug the target head adapter into the MCU socket (or surface-mount adapter) of the target
system.
6. Replace the access panel. (The target cable must run through the slit in the station-module
enclosure.)
2.5.4 Power Connection
The final MMDS connection is line power. The MMDS power switch is the rocker
switch on the left side of the station module. Set the power switch to OFF.
Insert the female end of the power cord into the power cord socket. Then plug the
other end of the cord into a line-power outlet and set the power switch to ON. The
green LED on the front of the station module lights to confirm system power.