259
10.8 CLK Synchronous Mode
• SCR regist er
•PEN: 0
• P, SBL , A/D: These bits are invalid.
• CL: 1
• REC: 0 (for in itialization)
• RXE, TXE : At least one must be set to 1.
•SSR register
• 1 for usin g interrupts or 0 for using no interrupt
• TIE: 0
❍Start of communication
Writing to the SODR register starts communication. Dummy transmission da ta must be written
to the SODR register, even for reception only.
❍End of communication
The end of communication can be detected by the fact that the RDRF flag of the SSR register
changes to "1". Check the ORE bit of the SSR register to determine whe ther communication
has been successful.