275
11.3 Data Register (ADCR)
11.3 Data Register (ADCR)

The data register (ADCR) is used to store a digital value that is the conversion result.

Configuration of Data Register (ADCR)
The configuration of the data register (ADCR) is shown below:
The value stored in this register is updated whenever on e cycle of conversion is completed.
Normally, the value converted last is stored.
The value of this register is undefined when the register is reset.
Reading the high-order bits 10 to 15 results in "0".
The conversion data protection function is supported. S ee Section 11.5, "Conversion Data
Protection Function," for this function.
bit 15 14 13 12 11 10 9 8
ADCR
Address:000038
H
000000XX
RRRRRRRR
bit 76543210
XXXXXXXX
RRRRRRRR
98
76543210
Bit attribute
Bit attribute
Initial value
Initial value