| 5.3 Host Commands | |
|
|
|
|
|
| Word | Value | Description |
|
|
|
|
|
|
| 21 | X’0000’ | Undefined |
|
|
|
|
|
|
| 22 | X’0004’ | Number of ECC bytes transferred at READ LONG or |
|
|
|
| WRITE LONG command |
|
|
|
|
|
|
| – | Firmware revision (ASCII code) *3 |
| |
|
|
|
|
|
| – | Model name (ASCII code) *4 |
| |
|
|
|
|
|
| 47 | X’8020’ | Maximum number of sectors per interrupt on |
|
|
|
| READ/WRITE MULTIPLE command |
|
|
|
|
|
|
| 48 | X’0000’ | Reserved |
|
|
|
|
|
|
| 49 | X’0B00’ | Capabilities *5 |
|
|
|
|
|
|
| 50 | X’0000’ | Reserved |
|
|
|
|
|
|
| 51 | X’0200’ | PIO data transfer mode *6 |
|
|
|
|
|
|
| 52 | X’0000’ | Reserved |
|
|
|
|
|
|
| 53 | X’0003’ | Enable/disable setting of words |
|
|
|
|
|
|
| 54 | (Variable) | Number of current Cylinders |
|
|
|
|
|
|
| 55 | (Variable) | Number of current Head |
|
|
|
|
|
|
| 56 | (Variable) | Number of current sectors per track |
|
|
|
|
|
|
| (Variable) | Total number of current sectors |
| |
|
|
|
|
|
| 59 | *8 | Transfer sector count currently set by READ/WRITE |
|
|
|
| MULTIPLE command *8 |
|
|
|
|
|
|
| X’00409980’ | Total number of user addressable sectors (LBA mode only) |
| |
|
| X’0060E640’ | MHA2021AT: X’00409980’ |
|
|
|
| MHA2032AT: X’0060E640’ |
|
|
|
|
|
|
| 62 | X’0000’ | Reserved |
|
|
|
|
|
|
| 63 | X’xx07’ | Multiword DMA transfer mode *9 |
|
|
|
|
|
|
| 64 | X’0003’ | Advance PIO transfer mode support status *10 |
|
|
|
|
|
|
| 65 | X’0078’ | Minimum multiword DMA transfer cycle time per word : |
|
|
|
| 120 [ns] |
|
|
|
|
|
|
| 66 | X’0078’ | Manufacturer’s recommended DMA transfer cycle time : |
|
|
|
| 120 [ns] |
|
|
|
|
|
|
| 67 | X’00F0’ | Minimum PIO transfer cycle time without IORDY flow |
|
|
|
| control : 240 [ns] |
|
|
|
|
|
|
| 68 | X’0078’ | Minimum PIO transfer cycle time with IORDY flow control |
|
|
|
| : 120 [ns] |
|
|
|
|
|
|
| X’00’ | Reserved |
| |
|
|
|
|
|
| 80 | X’000E’ | Major version number *11 |
|
|
|
|
|
|