5.1 Physical Interface

Table 5.1 Signal assignment on the interface connector

Pin No.

Signal

Pin No.

Signal

 

 

 

 

A

ENCSEL

B

GND

C

ENCSEL

D

MSTR

E

(KEY)

F

(KEY)

1

RESET–

2

GND

3

DATA7

4

DATA8

5

DATA6

6

DATA9

7

DATA5

8

DATA10

9

DATA4

10

DATA11

11

DATA3

12

DATA12

13

DATA2

14

DATA13

15

DATA1

16

DATA14

17

DATA0

18

DATA15

19

GND

20

(KEY)

21

DMARQ

22

GND

23

IOW–

24

GND

25

IOR–

26

GND

27

IORDY

28

CSEL

29

DMACK–

30

GND

31

INTRQ

32

IOCS16–

33

DA1

34

PDIAG

35

DA0

36

DA2

37

CS0–

38

CS1–

39

DASP–

40

GND

41

+5 VDC

42

+5 VDC

43

GND

44

unused

 

 

 

 

[signal]

[I/O]

[Description]

ENCSEL

I

This signal is used to set master/slave using the CSEL signal (pin 28).

 

 

Pins A and C Open: Sets master/slave by the MSTR signal

 

 

without using the CSEL signal.

 

 

Short: Sets master/slave using the CSEL signal.

 

 

The MSTR signal is ignored.

C141-E042-01EN

5-3

Page 64
Image 64
Fujitsu MHA2021AT, MHA2032AT manual Signal assignment on the interface connector, Dasp GND, Encsel