Interface

command is used for checking ECC function by combining with the WRITE LONG command.

Number of ECC bytes to be transferred is fixed to 4 bytes and cannot be changed by the SET FEATURES command.

The READ LONG command supports only single sector operation.

At command issuance (I/O registers setting contents)

1F7H(CM)

0

0

1

0

 

0

0

1

R

 

 

 

 

 

 

 

1F6H(DH)

×

L

×

DV

 

Head No. /LBA [MSB]

 

 

 

 

 

 

 

 

 

1F5H(CH)

Cylinder No. [MSB] / LBA

 

 

 

1F4H(CL)

Cylinder No. [LSB] / LBA

 

 

 

 

1F3H(SN)

Sector No. / LBA [LSB]

 

 

 

 

1F2H(SC)

01

 

 

 

 

 

 

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R= 0 with Retry R = 1 without Retry

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

1F6H(DH)

×

 

L

×

DV

Head No. /LBA [MSB]

 

 

 

 

 

 

1F5H(CH)

Cylinder No. [MSB] / LBA

1F4H(CL)

Cylinder No. [LSB] / LBA

1F3H(SN)

Sector No. / LBA [LSB]

1F2H(SC)

00 (*1)

 

 

 

 

1F1H(ER)

Error information

 

 

*1 If the command is terminated due to an error, this register indicates 01.

(18) WRITE LONG (X’32’ or X’33’)

This command operates similarly to the READ SECTOR(S) command except that the device writes the data and the ECC bytes transferred from the host system to the disk medium. The device does not generate ECC bytes by itself. The WRITE LONG command supports only single sector operation.

The number of ECC bytes to be transferred is fixed to 4 bytes and can not be changed by the SET FEATURES command.

5-44

C141-E042-01EN

Page 105
Image 105
Fujitsu MHA2032AT, MHA2021AT manual Interface