Interface

Sector Count register value

Point of timer

 

 

 

0

[X’00’]

30 minutes

 

 

 

1 to 3

[X’01’ to X’03’]

15 seconds

 

 

 

4 to 240

[X’04’ to X’F0’]

(Value ×5) seconds

 

 

 

241 to 251

[X’F1’ to X’FB’]

30 minutes

 

 

 

252

[X’FC’]

21 minutes

 

 

 

253

[X’FD’]

30 minutes

 

 

 

254 to 255

[X’FE’ to X’FF’]

21 minutes 15 seconds

 

 

 

attention: The automatic power-down is excuted if no command is coming for 30 min. (default)

At command issuance (I/O registers setting contents)

1F7H(CM)

X’97’ or X’E3’

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

 

×

DV

xx

 

 

 

 

 

 

 

1F5H(CH)

xx

 

 

 

 

 

1F4H(CL)

xx

 

 

 

 

 

1F3H(SN)

xx

 

 

 

 

 

1F2H(SC)

Period of timer

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

xx

 

 

 

 

 

 

1F5H(CH)

xx

 

 

 

 

1F4H(CL)

xx

 

 

 

 

1F3H(SN)

xx

 

 

 

 

1F2H(SC)

xx

 

 

 

 

1F1H(ER)

Error information

 

 

 

 

 

 

 

 

5-48

C141-E042-01EN

Page 109
Image 109
Fujitsu MHA2032AT, MHA2021AT manual ’97’ or X’E3’