3.5.2Factory default setting

Figure 3.15 shows the default setting position at the factory. (Master device setting)

DC Power

Connector

Interface Connector

Figure 3.15 Factory default setting

3.5.3Jumper configuration

(1)Device type

Master device (device #0) or slave device (device #1) is selected.

2

4

6

8

2

4

6

8

= shorted

1

3

5

7

9

1

3

5

7

9

(a)

Master device

(b)

Slave device

Figure 3.16 Jumper setting of master or slave device

Note:

When the device type is set by the jumper on the device, the device should not be configured for cable selection.

(2)Cable Select (CSEL)

In Cable Select mode, the device can be configured either master device or slave device. For use of Cable Select function, Unique interface cable is needed.

3 - 14

C141-E110-02EN

Page 43
Image 43