Table 4.1 Transfer rate of each zone

MPG3153AT/3307AT

Zone

Cylinder

Transfer rate

 

 

[MB/s]

 

 

 

0

0 to 2655

38.59

 

 

 

1

2656 to 5311

38.59

 

 

 

2

5312 to 6527

38.04

 

 

 

3

6528 to 9151

36.71

 

 

 

4

9152 to 11839

35.29

 

 

 

5

11840 to 13823

34.12

 

 

 

6

13824 to 15743

32.94

 

 

 

7

15744 to 18751

30.98

 

 

 

8

18752 to 19583

30.59

 

 

 

9

19584 to 21887

29.02

 

 

 

10

21888 to 24191

27.45

 

 

 

11

24192 to 25631

26.35

 

 

 

12

25632 to 27039

25.29

 

 

 

13

27040 to 28895

23.53

 

 

 

14

28896 to 25927

22.75

 

 

 

MPG3102AT/3204AT/3409AT

Zone

Cylinder

Transfer rate

 

 

[MB/s]

 

 

 

0

0 to 3231

49.80

 

 

 

1

3232 to 5727

48.47

 

 

 

2

5728 to 9055

46.47

 

 

 

3

9056 to 11071

45.10

 

 

 

4

11072 to 13055

43.76

 

 

 

5

13056 to 15743

41.76

 

 

 

6

15744 to 17663

40.47

 

 

 

7

17664 to 20031

38.59

 

 

 

8

20032 to 22335

36.71

 

 

 

9

22336 to 23999

35.29

 

 

 

10

24000 to 25375

34.12

 

 

 

11

25376 to 27135

32.55

 

 

 

12

27136 to 28799

30.98

 

 

 

13

28800 to 30431

29.41

 

 

 

14

30432 to 30783

27.45

 

 

 

The MPU transfers the data transfer rate setup data to the RDC that includes the time base generator circuit to change the data transfer rate.

C141-E110-02EN

4 - 11

Page 58
Image 58
Fujitsu MPG3XXXAT manual Transfer rate of each zone