Table 4.1 Transfer rate of each zone
MPG3153AT/3307AT
Zone | Cylinder | Transfer rate |
|
| [MB/s] |
|
|
|
0 | 0 to 2655 | 38.59 |
|
|
|
1 | 2656 to 5311 | 38.59 |
|
|
|
2 | 5312 to 6527 | 38.04 |
|
|
|
3 | 6528 to 9151 | 36.71 |
|
|
|
4 | 9152 to 11839 | 35.29 |
|
|
|
5 | 11840 to 13823 | 34.12 |
|
|
|
6 | 13824 to 15743 | 32.94 |
|
|
|
7 | 15744 to 18751 | 30.98 |
|
|
|
8 | 18752 to 19583 | 30.59 |
|
|
|
9 | 19584 to 21887 | 29.02 |
|
|
|
10 | 21888 to 24191 | 27.45 |
|
|
|
11 | 24192 to 25631 | 26.35 |
|
|
|
12 | 25632 to 27039 | 25.29 |
|
|
|
13 | 27040 to 28895 | 23.53 |
|
|
|
14 | 28896 to 25927 | 22.75 |
|
|
|
MPG3102AT/3204AT/3409AT
Zone | Cylinder | Transfer rate |
|
| [MB/s] |
|
|
|
0 | 0 to 3231 | 49.80 |
|
|
|
1 | 3232 to 5727 | 48.47 |
|
|
|
2 | 5728 to 9055 | 46.47 |
|
|
|
3 | 9056 to 11071 | 45.10 |
|
|
|
4 | 11072 to 13055 | 43.76 |
|
|
|
5 | 13056 to 15743 | 41.76 |
|
|
|
6 | 15744 to 17663 | 40.47 |
|
|
|
7 | 17664 to 20031 | 38.59 |
|
|
|
8 | 20032 to 22335 | 36.71 |
|
|
|
9 | 22336 to 23999 | 35.29 |
|
|
|
10 | 24000 to 25375 | 34.12 |
|
|
|
11 | 25376 to 27135 | 32.55 |
|
|
|
12 | 27136 to 28799 | 30.98 |
|
|
|
13 | 28800 to 30431 | 29.41 |
|
|
|
14 | 30432 to 30783 | 27.45 |
|
|
|
The MPU transfers the data transfer rate setup data to the RDC that includes the time base generator circuit to change the data transfer rate.
| 4 - 11 |