Table 5.4 Command code and parameters (2 of 2)

Command name

 

 

Command code (Bit)

 

 

 

Parameters used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

 

5

4

3

2

 

1

0

FR

 

SC

SN

CY

DH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STANDBY IMMEDIATE

1

0

 

0

1

0

1

 

0

0

N

 

N

N

N

 

D

 

1

1

 

1

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLEEP

1

0

 

0

1

1

0

 

0

1

N

 

N

N

N

 

D

 

1

1

 

1

0

0

1

 

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK POWER MODE

1

0

 

0

1

1

0

 

0

0

N

 

N

N

N

 

D

 

1

1

 

1

0

0

1

 

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMART

1

0

 

1

1

0

0

 

0

0

Y

 

Y

Y

Y

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLUSH CACHE

1

1

 

1

0

0

1

 

1

1

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY DISABLE PASSWORD

1

1

 

1

1

0

1

 

1

0

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY ERASE PREPARE

1

1

 

1

1

0

0

 

1

1

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY ERASE UNIT

1

1

 

1

1

0

1

 

0

0

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY FREEZE LOCK

1

1

 

1

1

0

1

 

0

1

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY SET PASSWORD

1

1

 

1

1

0

0

 

0

1

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY UNLOCK

1

1

 

1

1

0

0

 

1

0

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET MAX ADDRESS

1

1

 

1

1

1

0

 

0

1

N

 

Y

Y

Y

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ NATIVE MAX ADDRESS

1

1

 

1

1

1

0

 

0

0

N

 

N

N

N

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

FR : Features Register

CY: Cylinder Registers

SC : Sector Count Register

DH : Drive/Head Register

SN : Sector Number Register

 

R: R = 0 or 1

Y: Necessary to set parameters

Y*: Necessary to set parameters under the LBA mode.

N:Necessary to set parameters (The parameter is ignored if it is set.) N*: May set parameters

D: The device parameter is valid, and the head parameter is ignored.

D*: The command is addressed to the master device, but both the master device and the slave device execute it.

X: Do not care

C141-E110-02EN

5 - 15

Page 82
Image 82
Fujitsu MPG3XXXAT manual Command code and parameters 2