108 SPARC Enterprise T5440 Server Service Manual • June 2011
Related Information
“CMP and Memory Module Device Identifiers” on page107
“Performing Node Reconfiguration” on page159
Servicing FB-DIMMs
“Remove FB-DIMMs” on page108
“Install FB-DIMMs” on page109
“Verify FB-DIMM Replacement” on page110
“Add FB-DIMMs” on page113
“FB-DIMM Configuration” on page113
“FB-DIMM Device Identifiers” on page 116
“FB-DIMM Fault Button Locations” on page 117

Remove FB-DIMMs

Before you begin, complete these tasks:
Read the section, “Safety Information” on page63.
Power off the server, using one of the methods described in the section, “Powering
Off the System” on page67.
“Extend the Server to the Maintenance Position” on page70
“Perform Electrostatic Discharge – Antistatic Prevention Measures” on page73
“Remove the Top Cover” on page73
“Remove a CMP/Memory Module” on page104
Do the following:
1. If you are removing a faulty FB-DIMM, determine which FB-DIMM you want
to remove.
Four CMP/memory pairs
(full configurations)
XXXX
Configuration
CMP3
MEM3
CMP1
MEM1
CMP2
MEM2
CMP0
MEM0