112 SPARC Enterprise T5440 Server Service Manual • June 2011
Note – Depending on the configuration of ILOM POST variables and whether
POST-detected faults or not, the system might boot, or the system might remain at
the ok prompt. If the system is at the ok prompt, type boot.
d. Return the virtual keyswitch to Normal mode.
e. Switch to the system console and issue the Solaris OS fmadm faulty
command.
No memory faults should be displayed.
If faults are reported, refer to the diagnostics flowchart in FIGURE: Diagnostic
Flowchart on page14 for an approach to diagnose the fault.
4. Switch to the ILOM command shell.
5. Run the show faulty command.
If the fault was detected by the host and the fault information persists, the
output will be similar to the following example:
If the show faulty command does not report a fault with a UUID, then you
do not need to proceed with the following step because the fault is cleared.
6. Run the set command.
-> set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
# fmadm faulty
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
-> set /SYS/MB/CPU0/CMP0/BR0/CH1/D0 clear_fault_action=True
Are you sure you want to clear /SYS/MB/CPU0/CMP0/BR0/CH1/D0 (y/n)? y
Set ’clear_fault_action’ to ’true