Managing Faults 53
1. After replacing a faulty FRU, at the ILOM prompt use the show faulty
command to identify POST-detected faults.
Faults detected by POST are distinguished from other kinds of faults by the text:
Forced fail. No UUID number is reported. Refer to EXAMPLE: Fault Detected
by POST on page54.
If no fault is reported, you do not need to do anything else. Do not perform the
subsequent steps.
2. Use t he component_state property of the component to clear the fault and
remove the component from the ASR blacklist.
Use the FRU name that was reported in the fault in Step1:
The fault is cleared and should not show up when you run the show faulty
command. Additionally, the Service Required LED is no longer on.
3. Reset the server.
You must reboot the server for the component_state property to take effect.
4. At the ILOM prompt, use the show faulty command to verify that no faults
are reported.
-> set /SYS/MB/CPU0/CMP0/BR1/CH0/D0 component_state=Enabled
-> show faulty
Target | Property | Value
--------------------+------------------------+------------------
->