110 SPARC Enterprise T5440 Server Service Manual • June 2011
“Power On the Server” on page157
Verify FB-DIMM Replacement
1. Access the ILOM -> prompt.
Refer to the Integrated Lights Out Manager 3.0 Supplement for the SPARC Enterprise
T5440 Server for instructions.
2. Run the show faulty command to determine how to clear the fault.
The method you use to clear a fault depends on how the fault is identified by the
showfaults command.
Examples:
If the fault is a host-detected fault (displays a UUID), continue to Step3 . For
example:
In most cases, if the fault was detected by POST and resulted in the FB-DIMM
being disabled (such as the following example), the replacement of the faulty
FB-DIMM is detected when the service processor is power cycled. In this case,
the fault is automatically cleared from the system.
If the fault is still displayed by the show faulty command, then run the set
command to enable the FB-DIMM and clear the fault.
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 21 16:40:56
/SP/faultmgmt/0/ | timestamp | Dec 21 16:40:56 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CPU0/CMP0/BR1/CH0/D0
faults/0 | | Forced fail(POST)