38 SPARC Enterprise T5440 Server Service Manual • June 2011
Example showing a fault that was detected by the PSH technology. These kinds
of faults are distinguished from other kinds of faults by the presence of a
sunw-msg-id and by a UUID.
Example showing a fault that was detected by POST. These kinds of faults are
identified by the message Forced fail reason where reason is the name of the
power-on routine that detected the failure.
Example showing a fault in the External I/O Expansion Unit. These faults can
be identified by the text string Ext FRU or Ext sensor at the beginning of the
fault description.
The text string Ext FRU indicates that the specified FRU is faulty and should
be replaced. The text string Ext sensor indicates that the specified FRU
contains the sensor that detected the problem. In this case, the specified FRU
may not be faulty. Contact service support to isolate the problem.
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/MEM0/CMP0/BR1/CH1/D1
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 21 16:40:56
/SP/faultmgmt/0/ | timestamp | Dec 21 16:40:56
faults/0 | |
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CPU0/CMP0/CMP0/BR1/CH0/D0
faults/0 | Forced fail(POST)
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/IOX@X0TC/IOB1/LINK
/SP/faultmgmt/0 | timestamp | Feb 05 18:28:20
/SP/faultmgmt/0/ | timestamp | Feb 05 18:28:20