Managing Faults 47
In the following example, POST reports a memory error at FB-DIMM location
/SYS/MB/CPU0/CMP0/BR1/CH0/D0. The error was detected by POST running on
core 7, strand 2.
EXAMPLE: show Command Output
Perform further investigation if needed.
If POST detects a faulty device, the fault is displayed and the fault information is
passed to the service processor for fault handling. Faulty FRUs are identified in
fault messages using the FRU name.
The fault is captured by the service processor, where the fault is logged, the
Service Required LED is lit, and the faulty component is disabled. See EXAMPLE:
Fault Detected by POST on page 54.
Run the ILOM show faulty command to obtain additional fault information.
In this example, /SYS/MB/CPU0/CMP0/BR1/CH0/D0 is disabled. The system can
boot using memory that was not disabled until the faulty component is replaced.
Note – You can use ASR commands to display and control disabled components. See
“Disabling Faulty Components” on page55.
Related Information
“Diagnostic Flowchart” on page13
“POST Fault Management Overview” on page22
7:2>
7:2>ERROR: TEST = Data Bitwalk
7:2>H/W under test = /SYS/MB/CPU0/CMP0/BR1/CH0/D0
7:2>Repair Instructions: Replace items in order listed by 'H/W
under test' above.
7:2>MSG = Pin 149 failed on /SYS/MB/CPU0/CMP0/BR1/CH0/D0 (J792)
7:2>END_ERROR
7:2>Decode of Dram Error Log Reg Channel 2 bits
60000000.0000108c
7:2> 1 MEC 62 R/W1C Multiple corrected
errors, one or more CE not logged
7:2> 1 DAC 61 R/W1C Set to 1 if the error
was a DRAM access CE
7:2> 108c SYND 15:0 RW ECC syndrome.
7:2>
7:2> Dram Error AFAR channel 2 = 00000000.00000000
7:2> L2 AFAR channel 2 = 00000000.00000000