Managing Faults 31
Related Information
“Diagnostic Flowchart” on page13
“Change POST Parameters” on page31
“Run POST in Maximum Mode” on page32
“Detecting Faults Using POST” on page46
“Clear Faults Detected During POST” on page52
SPARC Enterprise T5440 Server Installation and Setup Guide
SPARC Enterprise T5440 Server Administration Guide
Change POST Parameters
1. Access the ILOM prompt.
See “Connecting to the Service Processor” on page 25.
2. Use the ILOM commands to change the POST parameters.
Refer to Component Fault on page 35 for a list of ILOM POST parameters and
their values.
The set /SYS keyswitch_state command sets the virtual keyswitch
parameter. For example:
To change individual POST parameters, you must first set the keyswitch_state
parameter to normal. For example:
normal POST output displays all test and informational
messages.
max POST displays all test, informational, and some
debugging messages.
-> set /SYS keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’
-> set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
-> set /HOST/diag property=Min
Parameter Values Description