Environmental specifications

The following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.

VariableRequirements

 

 

Temperature

Maximum rate of change = 10° C per hour

 

 

Nonoperating

-48.3° to 65.5° C (-55° to 150° F)

 

 

Operating

5° to 35° C (41° to 95° F); derated 0.5° C for every

 

1000 ft. (305 m)

 

 

Altitude

10,000 ft. max

 

 

Humidity

 

 

 

Nonoperating

95% relative (noncondensing) at 30° C (86° F)

 

 

Operating wet

Not to exceed 33 °C (91.4° F) (with diskette drive or

bulb

hard drive)

 

 

Shock

 

 

 

Operating

2.0 g, 11 msec, 1/2 sine

 

 

Packaged

Operational after 30-inch free fall (cosmetic damage

 

might occur)

 

 

AC Input Power

 

 

 

100-120 V

100-120 V, 6 A, 50/60 Hz

 

 

200-240 V

200-240 V, 3 A, 50/60 Hz

 

 

134System Specifications