Gun Overview

Table 1 . Key for Figs. 2–9.

 

 

 

 

 

Item

Description

Purpose

VA

Voltage Adjustment Switch

Two-position switch sets smart

 

 

gun voltage to low setting (LO) or

 

 

high setting (HI). This switch is

 

 

functional in Operating Mode and

 

 

in Diagnostic Mode.

LO

Low Voltage Mode Indicator

Lights (blue) when the smart gun

 

 

is set to Low Voltage.

kV

Voltage (kV) Display

Displays actual spraying voltage

 

 

of the gun, in kV. In Operating

 

 

Mode, display is a bar graph.

 

 

In Diagnostic Mode, voltage is

 

 

displayed as a number.

uA

Current (uA) Display

Displays actual spraying current

 

 

of the gun, in uA. In Operating

 

 

Mode, display is a bar graph.

 

 

In Diagnostic Mode, current is

 

 

displayed as a number.

LS

LO SET button

Press momentarily to enter the

 

 

Low Voltage Setting screen.

 

 

Press and hold for approximately 5

 

 

seconds to enter or exit Diagnostic

 

 

Mode.

 

 

While in Diagnostic Mode, press

 

 

momentarily to advance through

 

 

screens.

 

 

While on the Low Voltage Lock

 

 

Screen (in Diagnostic Mode),

 

 

press and hold to turn the lock on

 

 

or off.

LV

Low Voltage Display

Displays the low voltage setting

 

 

as a number. The setting can be

 

 

changed. See Fig. 4.

LK

Low Voltage Locked

Appears if the low voltage setting

 

 

is locked. See Fig. 5 and Fig. 9.

3A2495C

11

Page 11
Image 11
Graco 3A2495C important safety instructions Key for Figs Description Purpose