Graco 3A2495C important safety instructions See Clean the Gun Daily, Replacement, page 52

Models: 3A2495C

1 68
Download 68 pages 10.92 Kb
Page 38
Image 38

Troubleshooting

Problem

Cause

Solution

 

 

 

Voltage/current display stays red

Gun is too close to the part being

Gun should be 8–12 in. (200–300

(smart guns only).

sprayed.

mm) from the part.

 

Check fluid resistivity.

See

 

 

Check Fluid Resistivity, page 26.

 

Dirty gun.

See Clean the Gun Daily, page 29.

 

 

 

ES or Hz indicator is amber.

Alternator speed is too low.

Increase air pressure until

 

 

indicator is green. To avoid

 

 

over-atomization, use the

 

 

atomizing air restrictor valve to

 

 

reduce the atomizing air to the air

 

 

cap.

ES or Hz indicator is red.

Alternator speed is too high.

Decrease air pressure until

 

 

indicator is green.

Error display appears and Hz

Smart module has lost

Check for good connections

indicator is red (Smart guns only).

communication with the power

between Smart Module and

 

supply.

power supply. See Smart Module

 

 

Replacement, page 52 and

 

 

Power Supply Removal and

 

 

Replacement, page 45.

38

3A2495C

Page 38
Image 38
Graco 3A2495C important safety instructions See Clean the Gun Daily, Replacement, page 52