Gun Setup

Check Fluid Resistivity

To reduce the risk of fire, explosion, or electric shock, check the fluid resistivity in a non-hazardous area only. Resistance Meter 722886 and Probe 722860 are not approved for use in a hazardous area.

Failure to follow this warning could cause fire, explosion, or electric shock and result in serious injury and property damage.

Graco Part No. 722886 Resistance Meter and 722860 Probe are available as accessories to check that the resistivity of the fluid being sprayed meets the requirements of an electrostatic air-assisted spray system.

Follow the instructions included with the meter and probe. Readings of 25 megohms-cm and above provide the best electrostatic results.

Table 4 . Fluid Resistivity Levels

Megohms-cm

1–5

5–25

25–200

200–2000

Test elec-

Good elec-

Best elec-

Good elec-

trostatic

trostatic

trostatic

trostatic

perfor-

results

results

results

mance

 

 

 

Check Fluid Viscosity

To check fluid viscosity you will need:

a viscosity cup

a stopwatch.

1.Completely submerge the viscosity cup in the fluid. Lift the cup out quickly, starting the stopwatch as soon as the cup is completely removed.

2.Watch the stream of fluid coming from the bottom of the cup. As soon as there is a break in the stream, shut off the stopwatch.

3.Record the fluid type, elapsed time, and size of the viscosity cup.

4.If the viscosity is too high or too low, contact the material supplier. Adjust as necessary.

Flush Before Using Equipment

The equipment was tested in fluid at the factory. To avoid contaminating your fluid, flush the equipment with a compatible solvent before using the equipment.

26

3A2495C

Page 26
Image 26
Graco 3A2495C important safety instructions Check Fluid Resistivity, Check Fluid Viscosity, Flush Before Using Equipment