3–8 SCANTEAM 5700 User’s Guide
Keyboard Style Modifiers
This programming selection allows you to program special keyboard features,
such as CTRL+ codes and Turbo Mode.
Control + ASCII Mode On – If you scan this selection, the scanner sends key
combinations for ASCII control characters for values 00–1F. Refer to page 6–1
for CTRL+ Values. Default = Off
Turbo Mode – Selecting Turbo Mode On, (for the IBM AT only), programs the
scanner to send characters to the terminal faster. Default = Off
Numeric Keypad Mode – Selecting Numeric Keypad Mode On sends numeric
characters as if entered from a numeric keypad. Default = Off
Default All – This sets all Keyboard Style Modifiers to their default states
(Control + ASCII Mode Off, Turbo Mode Off, Numeric Keypad Mode Off).
Automatic Direct Connect – When Emulate External Keyboard has been
selected (page 3–7), Automatic Direct Connect Mode keeps the integrated
keyboard from becoming permanently disabled. Default = Off
Keyboard Style Modifiers
Default All
Control + ASCII Mode On Control + ASCII Mode Off
Turbo Mode On
Numeric Keypad Mode On Numeric Keypad Mode Off
Turbo Mode Off
Automatic Direct Connect
Mode On Automatic Direct Connect
Mode Off
Note: This selection disabled the keyboard for the entire duration of the bar code
transmission.