Laser Output only

5700–X4

(Laser Compatible Bar Image +12VDC Input*)

Conventional laser data format is provided at the modular connector in the scanner handle.

Interface cables normally supplied with scanner model 5700–X0 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

 

9 Pin Type D Female

P1 connects to the

 

P2 connects to

scanner handle.

 

your terminal.

 

Pin 1

 

5

1

 

Pin 10

 

9

6

 

 

View A–A

 

 

 

 

 

P1

Signal

Function

 

P2

9

SOS

Start of Scan

 

1

Good Read

Turn on Good Read LED or Beeper

5

3

Ground

Supply Ground

 

4

 

7

Data

Digital Bar Code Data Output

6

2

Trigger

Trigger Signal to Decoder

8

5

Enable

Laser Enable

 

3

 

6

+12VDC

Power Connection

1

9

 

 

 

10 VCC (Connected for AutoTrigger**)

N/C

8

*Note: Cable supports decoders which supply +12V on pin 9 ONLY.

**Note: Reference the Cable Matrix for correct AutoTrigger cable.