Wand Emulation

5700–X1, 5700–X2

Conventional wand data format is provided at the modular connector in the scanner handle.

Interface cables normally supplied with scanner model 5700–X1 and 5700–X2 are terminated with an 10 pin modular plug (P1) and a 9 pin Type D (Squeeze–to–release) connector (P2) that is compatible with all Welch Allyn terminals. See chart below.

P1

P2

10 Pin Modular Plug

9 Pin Type D Female

P1 connects to the

P2 connects to

scanner handle.

your terminal.

P1

2

3

4

6

7

Pin 1

5

1

Pin 10

9

6

 

View A–A

 

 

Signal

Function

P2

Braid

Cord Shield

8

Prog 1

Tied to 5 Volt Power

 

Ground

Supply Ground

7

Barcode

Bar Code Data Output

2

+5VDC

5 Volt Power Connection

4

 

 

7–4

SCANTEAM 5700 User’s Guide