Laser Output
(Laser Compatible Bar Image, Low Power/Dual Interface)
Conventional laser data format is provided at the modular connector in the scanner handle.
Interface cables normally supplied with scanner model
P1 | P2 |
10 Pin Modular Plug | 9 Pin Type D Female | ||||
P1 connects to the | P2 connects to | ||||
scanner handle. |
| your terminal. | |||
| Pin 1 | 5 |
| 1 | |
| Pin 10 | 9 | View | 6 | |
|
|
| |||
|
|
|
| ||
P1 | Signal | Function |
| P2 | |
9 | SOS | Start of Scan |
| 1 | |
Data | Digital Bar Code Data Output | ||||
6 | 2 | ||||
Good Read | Turn on Good Read LED or Beeper | ||||
5 | 3 | ||||
+5VDC | 5 Volt Power Connection |
| |||
7 |
| 9 | |||
Trigger | Trigger Signal to Decoder |
| |||
2 |
| 5 | |||
|
|
| |||
3 | Enable | Laser Enable |
| 6 | |
Ground | Supply Ground |
| |||
4 |
| 7 | |||
| Cord Shield | Braid | |||
8 | N/C | 8 | |||
|
| ||||
10 | N/C |
|
|
| |
1 | N/C |
|
|
|
SCANTEAM 5700 User’s Guide |