Transmission Rate Selection

This programming selection sets the transmission rate from 10 ips (inches per second) to 300 ips if the scanner is in Wand Emulation mode. Programming the transmission rate causes the data to be sent at the specified rate. The programmed transmission rate must be compatible with the device receiving the bar code data. Default = 25 ips (inches per second).

10

25

40

80

120

150

200

300

Wake Up Pulse Selection

This selection provides a “wake up” pulse on the sync line from the scanner to a portable terminal. This feature extends battery life of the portable terminal by waking up the terminal only when data is ready to be sent. Bar code data follows the wake up pulse after a 0.2 second delay. Default = Disable.

Enable

Disable

Output Polarity Selection [

This selection allows you to set the output logic convention for the digital output. The choices are White High (“Laser” output) and Black High.

Default = Black High.

White High

Black High

[In Laser Emulation mode, the default polarity is White High. In Wand Emulation mode, the default polarity is Black High.