Heat & Glo LifeStyle 6000XLS Step, Wiring the, For Standing Pilot Ignition Wiring, Fireplace

Models: 6000TR 6000XLT-CDN 6000XLS 6000ARCH

1 48
Download 48 pages 45.62 Kb
Page 34
Image 34
Step 8

34

Step 8

NOTE: Electrical wiring must be installed by a

Wiring the

licensed electrician.

Fireplace

Caution: Disconnect remote controls if you are

 

absent for extended time periods. This will

 

prevent accidental fireplace operation.

For Standing Pilot Ignition Wiring

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

!WARNING

DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED.

Optional Accessories

Optional fan and remote control kits require that 110- 120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Remote Wall Switch

Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.

!WARNING

DO NOT CONNECT 110-120 VAC TO THE REMOTE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION

 

WHEN SERVICING CONTROLS. WIRING

 

ERRORS CAN CAUSE IMPROPER AND

 

DANGEROUS OPERATION. VERIFY PROPER

 

OPERATION AFTER SERVICING.

NOTE: 6000XLT-CDN DOES NOT HAVE A LIMIT SWITCH.

Figure 31. Standing Pilot Ignition Wiring Diagram

Page 34
Image 34
Heat & Glo LifeStyle 6000XLS, 6000TR Step, Wiring the, For Standing Pilot Ignition Wiring, Fireplace, licensed electrician