Heat & Glo LifeStyle 6000XLS, 6000XLT-CDN, 6000TR, 6000ARCH manual Roof Pitch

Models: 6000TR 6000XLT-CDN 6000XLS 6000ARCH

1 48
Download 48 pages 45.62 Kb
Page 30
Image 30
Roof Pitch

30

1.Attach the flashing and apply sealant around the edges of the flashing base.

2.Attach the storm collar over the flashing joint and apply sealant between the storm collar and vertical pipe.

To seal the roof hole, and to divert rain and snow from the vent system:

Attach a flashing to the roof using nails, and use a non-hardening mastic around the edges of the flashing base where it meets the roof.

Attach a storm collar over the flashing joint to form a water-tight seal. Place non-hardening mastic around the joint, between the storm collar and the vertical pipe.

Slide the termination cap over the end of the vent pipe and rotate the pipe clockwise 1/4 turn.

 

HORIZONTAL OVERHANG

TERMINATION

 

CAP

VERTICAL WALL

 

2 FT.

2 FT. MIN.

MIN.

 

 

LOWEST

 

DISCHARGE

TERMINATION CAP

OPENING

 

X

 

12

 

ROOF PITCH IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

H (min.) ft.

flat to 6/12

1.0

6/12 to 7/12

1.25

over 7/12 to 8/12

1.5

over 8/12 to 9/12

2.0

over 9/12 to 10/12

2.5

over 10/12 to 11/12

3.25

over 11/12 to 12/12

4.0

over 12/12 to 14/12

5.0

over 14/12 to 16/12

6.0

over 16/12 to 18/12

7.0

over 18/12 to 20/12

7.5

over 20/12 to 21/12

8.0

Figure 27. Minimum Height from Roof to Lowest Discharge Opening

Page 30
Image 30
Heat & Glo LifeStyle 6000XLS, 6000XLT-CDN, 6000TR, 6000ARCH manual Roof Pitch