Heat & Glo LifeStyle 6000ARCH, 6000XLT-CDN DV-90D, DV-45D, DV-48D DV-36D, DV-12D, DV-09D, DV-06D

Models: 6000TR 6000XLT-CDN 6000XLS 6000ARCH

1 48
Download 48 pages 45.62 Kb
Page 11
Image 11
DV-90D

DV-90D

6-5/32"

(156 mm) DV-45DDV-48D

DV-45D

6-7/16"

 

 

(164 mm)

 

 

 

 

8-1/2"

 

 

 

 

 

(216 mm)

7-3/8" 5-7/8"

8-1/2"

(216 mm)

11-5/8"

11-1/16"

(295 mm)

(281 mm)

 

(187 mm) (149 mm)

8-5/8" (220 mm)

DV-12DDV-09D11-15/16" (303 mm)

6-1/2"

5-1/16"

(165 mm)

(129 mm)

 

8-5/8"

 

(220 mm)

 

DV-48D

DV-36D

47-3/4"

(1.2 m)

35-3/4"

(908 mm)

DV-12D

 

DV-09D

 

11-3/4"

8-3/4"

DV-06D

(298 mm)

5-3/4"

 

(222 mm)

 

(146 mm)

 

 

NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93 mm) AT EACH JOINT.

Figure 6. D-Series Direct Vent Component Specifications (5-inch inner pipe/ 8 5/8-inch outer pipe)