Heat & Glo LifeStyle 6000ARCH, 6000XLT-CDN Step Positioning Leveling, and Securing the, Fireplace

Models: 6000TR 6000XLT-CDN 6000XLS 6000ARCH

1 48
Download 48 pages 45.62 Kb
Page 31
Image 31
Step 4

Step 4

Positioning,

Leveling, and

Securing the

Fireplace

1.Place the fireplace into position.

2.Level the fireplace from side to side and from front to back.

3.Shim the fireplace with non-combus- tible material, such as sheet metal, as necessary.

4.Secure the fireplace to the framing by nailing or screwing

Step 5

The Gas Control

Systems

The diagram below shows how to properly position, level, and secure the fireplace.

Figure 28. Proper Positioning, Leveling, and

Securing of a Fireplace

!WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI). Models 6000XLT-CDN and 6000XLS have Standing Pilot Ignition only. Model 6000ARCH has DSI only. Model 6000TR has both Standing Pilot and DSI systems

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

!WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System

This system includes a 110V control valve, electronic module, and spark ignitor/flame sensor.

!WARNING: CONTINUOUS 110-120 VAC SERVICE MUST BE WIRED DIRECTLY TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.

!WARNING: DIRECT VENT PROPANE MODELS WITH DSI CONTROL SYSTEMS CANNOT BE USED IN