STANDING PILOT | NOTE: FLAMES TOO | DSI IGNITION |
CLOSE TO THE |
| |
| CERAMIC INSULATORS |
|
| CAN CAUSE NUISANCE |
|
| LOCKOUTS AND |
|
| ELECTRODE FAILURE. | IGNITOR |
|
| 3/8” (10mm) |
| CERAMIC |
|
| INSULATOR |
|
| 1/4" (6mm) |
|
Figure 29. Gas Controls Systems
32
Step 6
The Gas
Supply Line
NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes.
NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.
NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch (13 mm)
This gas fireplace is designed to accept a 1/2 inch
(13 mm) gas supply line. To install the gas supply line:
•A listed 1/2 inch (13 mm) manual
•The gas line may be run from either side of the fireplace provided the hole in the outer wrap does not exceed 2 inches in diameter and it does not penetrate the airtight box.
•The gap between the supply piping and gas ac- cess hole can be plugged with
•Locate the gas line access hole in the outer casing of the fireplace.
•Open the fireplace lower grille, insert the gas sup- ply line through the gas line hole, and connect it to the
•When attaching the pipe, support the control so that the lines are not bent or torn.
•After the gas line installation is complete, use a soap solution to carefully check all gas connections for leaks.
!WARNING: DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.