Heat & Glo LifeStyle 6000XLS, 6000XLT-CDN, 6000TR, 6000ARCH C. Vent Termination, Attic Firestop

Models: 6000TR 6000XLT-CDN 6000XLS 6000ARCH

1 48
Download 48 pages 45.62 Kb
Page 26
Image 26
Figure 24. Attic Firestop

26

This shows an attic installation.

1.Keep insulation away from the vent pipe at least 1 inch (25 mm).

If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole.

JOIST

CEILING

NAILS (4 REQUIRED)

CEILING FIRESTOP

Figure 24. Attic Firestop

C. Vent Termination

For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent:

Rotate and interlock the ends as described at the beginning of the Installing Vent Components section.

The termination kit should pass through the wall firestops from the exterior of the building.

Adjust the termination cap to its final exterior position on the building.

!WARNING

THE TERMINATION CAP MUST BE POSITIONED SO THAT THE ARROW IS POINTING UP.

For roundcap termination kits:

Use the exterior pipelock hole provided on the round flange of the wall firestop to secure the vent pipe in place.

For trapezoidal cap termination kits:

Using screws, secure the cap to the exterior wall through the flanges built into the cap.

Page 26
Image 26
Heat & Glo LifeStyle 6000XLS, 6000XLT-CDN, 6000TR, 6000ARCH manual C. Vent Termination, Attic Firestop