Heat Controller HSS, HTS SERIES SPLIT SYSTEM R-22Air Handler Characteristics, Equipment Selection

Models: HSS HTS SERIES SPLIT SYSTEM

1 48
Download 48 pages 27.01 Kb
Page 7
Image 7
Table 2: R-22 Air Handler Characteristics

T h e Q u a l i t y L e a d e r i n C o n d i t i o n i n g A i r

R e s i d e n t i a l S p l i t - 6 0 H z R 2 2 & R 4 1 0 A

R e v. : 5 J u n e , 2 0 0 8

Equipment Selection

Table 1b: GeoMax 2 (HTS) Air Handler Characteristics for Brands other than Above Models

 

Model*

Nominal

Evaporator

CFM

Capacity

 

Tons*

Temp (ºF)

(MBtuh)**

 

 

 

 

 

 

 

 

 

024

- Part Load

1.5

50

530

19.2 - 22.4

 

 

 

 

 

 

024

- Full Load

2.0

52

880

24.2 - 28.2

 

 

 

 

 

 

036

- Part Load

2.5

51

700

25.2 - 29.2

 

 

 

 

 

 

036

- Full Load

3.0

50

1200

34.5 - 40.1

 

 

 

 

 

 

048

- Part Load

3.5

47

1000

34.3 - 39.9

 

 

 

 

 

 

048

- Full Load

4.0

48

1650

46.3 - 53.8

 

 

 

 

 

 

060

- Full Load

5.0

48

1850

54.5 - 63.3

*Nominal tons are at ARI/ISO 13256-1 GLHP conditions. Two-stage units may be operated in single-stage mode if desired, where smaller capacity is required. For example, a model 026 may be used as a 1-1/2 ton unit if “locked” into 1st stage operation only. If PSC fan is used, unit must be “locked” into either 1st or 2nd stage. An ECM fan is required for two-stage operation and for ARI ratings. Size air handler for “Full Load” if operating in two-stage mode.

**When selecting an air handler based upon the above conditions, choose entering WB temperature of 67ºF. Use evaporator temperature, CFM and capacity requirements as listed above. The air handler capacity must be at least at the minimum capacity shown in the table in order for the ARI rating condition to be valid. See Figure 1 for an example selection.

Indoor Coil Selection - For HSS R-22 Units

Geothermal split system heat pumps with R-22 refrigerant are rated in the ARI directory with a “generic” indoor coil match and PSC fan. Selection of air handlers that attain the published ARI ratings must meet or exceed the specifications listed in Table

2.A TXV is required. Cap tubes and fixed orifices are not acceptable.

Table 2: R-22 Air Handler Characteristics

Model*

Nominal

Evaporator

CFM

Capacity

Tons*

Temp (ºF)

(MBtuh)**

 

 

 

 

 

 

 

018

1.5

50

600

18.5 - 21.3

 

 

 

 

 

024

2.0

47

800

25.5 - 29.3

 

 

 

 

 

030

2.5

49

1000

31.5 - 36.2

 

 

 

 

 

036

3.0

48

1200

37.0 - 42.5

 

 

 

 

 

042

3.5

45

1400

42.2 - 48.5

 

 

 

 

 

048

4.0

46

1600

50.0 - 57.5

 

 

 

 

 

060

5.0

45

2000

58.0 - 66.7

* Nominal tons are at ARI/ISO 13256-1 GLHP conditions.

**When selecting an air handler based upon the above conditions, choose entering WB temperature of 67ºF. Use evaporator temperature, CFM and capacity requirements as listed above. The air handler capacity must be at least at the minimum capacity shown in the table in order for the ARI rating condition to be valid. See Figure 1 for an example selection.

w w w. h e a t c o n t o l l e r. c o m

7

Page 7
Image 7
Heat Controller HSS, HTS SERIES SPLIT SYSTEM manual R-22Air Handler Characteristics, Equipment Selection