Function mode

 

Code

 

Function name

 

SJ300 Setting range

Initial data

Note

 

 

 

-FE/-FU/-F

 

 

 

 

 

 

 

 

 

 

H001

Autotuning selection

 

00(Invalid)/01( Valid(the motor does not rotate) )/

00

 

 

 

02( Valid(the motor rotates))

 

 

 

 

 

 

 

 

 

 

H002

1s t

motor constant selecti on

00(Hitachi general purpose motor data)/01( Autotuning data) /

00

 

 

 

 

 

 

 

02( Autotuning data with online autotuning)

 

 

 

H202

2nd motor constant selection

00(Hitachi general purpose motor data)/01( Autotuning data) /

00

 

 

 

 

 

 

 

02( Autotuning data with online autotuning)

 

 

 

H003

1s t

allowable motor selection

0.20-75.0(kW)

<0.2-160(kW)>

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H203

2nd allowable motor selection

0.20-75.0(kW)

<0.2-160(kW)>

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H004

1s t motor pole selection

 

2/4/6/8(pole)

4

 

 

H204

2nd motor pole selection

 

2/4/6/8(pole)

4

 

 

H005

1s t speed response setting

0.001-9.999/10.00-65.53

1.590

 

 

H205

2nd speed response setting

0.001-9.999/10.00-65.53

1.590

 

 

H006

1s t stabilized factor

 

0. - 255.

100.

 

 

H206

2nd stabilized factor

 

0. - 255.

100.

 

 

H306

3rd stabilized factor

 

0. - 255.

100.

 

 

H020

1s t

motor constant R1

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H220

2nd motor constant R1

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H021

1s t

motor constant R 2

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H221

2nd motor constant R 2

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H022

1s t

motor constant L

 

0.00-99.99/100.0-655.3( mH)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H222

2nd motor constant L

 

0.00-99.99/100.0-655.3( mH)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H023

1s t

motor constant I 0

 

0.00-99.99/100.0-655.3(A)

Set on

 

others

 

 

 

 

 

 

 

forwarding

 

H223

2nd motor constant I0

 

0.00-99.99/100.0-655.3(A)

Set on

 

 

 

 

 

 

 

 

 

forwarding

 

 

H024

s t

motor constant J

 

 

2

Set on

 

The

1

 

0.001-9.999/10.00-99.99/100.0-9999.( kgm )

forwarding

 

H224

2nd motor constant J

 

0.001-9.999/10.00-99.99/100.0-9999.( kgm2)

Set on

 

 

 

1s t

motor constant R1

 

 

 

forwarding

 

 

H030

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H230

2nd motor constant R1

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H031

1s t

motor constant R 2

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H231

2nd motor constant R 2

 

0.000-9.999/10.00-65.53(ohm)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H032

1s t

motor constant L

 

0.00-99.99/100.0-655.3( mH)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H232

2nd motor constant L

 

0.00-99.99/100.0-655.3( mH)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H033

1s t

motor constant I 0

 

0.00-99.99/100.0-655.3(A)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H233

2nd motor constant I0

 

0.00-99.99/100.0-655.3(A)

Set on

 

 

(Autotuning data)

 

forwarding

 

 

 

 

 

 

 

 

H034

1s t

motor constant J

 

0.001-9.999/10.00-99.99/100.0-9999.( kgm2)

Set on

 

 

 

forwarding

 

 

H234

2nd motor constant J

 

0.001-9.999/10.00-99.99/100.0-9999.( kgm2)

Set on

 

 

 

forwarding

 

 

H050

1s t

PI-control

proportion gain

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H250

2nd PI-control

proportion gain

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H051

1s t

PI-control

integration

gain

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H251

2nd PI-control integration gain

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H052

1s t

P-control

proportion

gain

0.01-10.00

1.00

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H252

2nd P-control

proportion

gain

0.01-10.00

1.00

 

 

setting

 

 

 

 

 

 

 

 

 

 

 

 

H060

1s t 0Hz-SLV limiter setting

0.-100.(%)

100.

 

 

H260

2nd 0Hz-SLV limiter setting

0.-100.(%)

100.

 

 

H070

PI-control proportion gain for

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

switching

 

 

 

 

 

 

 

 

 

 

 

 

H071

PI-control integration gain for

0.00-99.99/100.0-999.9/1000.(%)

100.0

 

 

switching

 

 

 

 

 

 

 

 

 

 

 

 

H072

P-control proportion gain for

0.00-10.00

1.00

 

 

switching

 

 

 

 

 

 

 

 

 

 

 

(Note) < > indicate the setting range of 75 to 150kW

1- 8

Page 11
Image 11
Hitachi L300P Series service manual Allowable motor selection 20-75.0kW 160kW