1- 9
Function mode
Code Function name SJ300 Setting range Initial data
-FE/-FU/-F Note
P001 Option1 operation selection
on error 00(TRP)/01(RUN) 00
P002 Option2 operation selection
on error 00(TRP)/01(RUN) 00
P010
Feed-back option selection 00(Invalid)/01(Valid) 00
P011 Encoder pulse number
setting 128.-9999./1000-6500(10000-65000) (pulse) 1024
P012
Control mode selection 00(ASR mode)/01(APR mode) 00
P013 Pulse train input mode
selection 00(Mode 0)/01(Mode 1)/02(Mode 2)/03(Mode 3) 00
P014 Orientation stop position
setting 0.-4095. 0.
P015
Orientation speed setting 0.00-99.99/100.0-120.0(Hz) 5.00
P016 Orientation direction
selection 00(Forward)/01(Reverse) 00
P017 Orientation completion range
setting 0.-9999./1000(10000) (pulse) 5
P018 Orientation completion delay
time setting 0.00-9.99(s) 0.00
P019 Electronic gear position
selection 00(Feedback)/01(Reference) 00
P020 Electronic gear numerator of
ratio setting 0.-9999. 1.
P021 Electronic gear denominator
of ratio setting 0.-9999. 1.
P022 Position control feed-forward
gain setting 0.00-99.99/100.0-655.3 0.00
P023 Position control loop gain
setting 0.00-99.99/100.0 0.50
P025 Compensation of secondary
resistor selection 00(Invalid)/01(Valid) 00
P026 Over-speed detect level
setting 0.00-99.99/100.0-150.0(%) 135.0
P027 Speed-error over detect level
setting 0.00-99.99/100.0-120.0(Hz) 7.50
P031 Digital input option input
mode selection (Acc/Dec) 00(operator)/01(option1)/02(option2) 00
P032 Stop position setting for
orientation input mode
selection 00(operator)/01(option1)/02(option2) 00
P044 DeviceNet running order of
monitoring timer setting 0.00-99.99s 1.00
P045 Setting in action of abnormal
communication 00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop) 0.
P046 Output assemble instance
Number setting 20,21,100 21
P047 Input assemble instance
Number setting 70,71,101 71
P048 Detect of idol mode for
motion setting 00(trip)/01(trip after deceleration stop)/02(invalid)/
03(free-run)04(deceleration stop) 01
P049 Pole setting of rotation speed 0-38(even only) 0
U001 User1 selection no/d001-P049 <-P032> no
U002 User2 selection no/d001-P049 <-P032> no
U003
User3 selection no/d001-P049 <-P032> no
U004
User4 selection no/d001-P049 <-P032> no
U005
User5 selection no/d001-P049 <-P032> no
U006
User6 selection no/d001-P049 <-P032> no
U007
User7 selection no/d001-P049 <-P032> no
U008
User8 selection no/d001-P049 <-P032> no
U009
User9 selection no/d001-P049 <-P032> no
U010 User10 selection no/d001-P049 <-P032> no
U011
User11 selection no/d001-P049 <-P032> no
U012
User12 selection no/d001-P049 <-P032> no

(Note 1) P044-P049 are displayed on a 0.4-55kW model.

User selection

Option