5.7 Unit replacement
Unit replacement can be done without rewiring of the logic signal.
(How to exchange)
•Remove terminal cover.
‚Reconfirm that the charge lamp is turned OFF.
ƒRemove the screws, right and left portion , like following figure. „ Plug out the logic terminal carefully.
… In case of plugging in to the new inverter, pay attention not to bend the connection pins.