SWITCHING BETWEEN AUTO/MANUAL DEHUMIDIFYING/DRY COOL OPERATION

The AUTO/MANUAL button allows you to set the temperature and humidity manually during dehumidifying/ dry cool operation.

The default setting is AUTO.

Press the AUTO/MANUAL button.

Switches to the manual mode if the machine is working in the auto dehu midifying/dry cool operation.

Switches to the auto mode if the machine is working in the manual dehu midifying/dry cool operation.

Example: Dehumidifying

Indicates MANUAL

ENGLISH

Setting Range of AUTO/MANUAL Operation

Adjustment Range of Dehumidifying Operation

 

Room Temperature

Humidity

 

 

 

Auto Dehumidifying

Auto-controlled

40%~70

operation

temperature ±3°C

 

 

 

 

Manual Dehumidifying

10°C~32°C

40%~70

operation

 

 

 

 

 

Adjustment Range of Dry Cool Operation

 

 

 

 

 

Room Temperature

Humidity

 

 

 

Auto dry cool

Auto-controlled

Automatically adjusted in the

operation

temperature ±3°C

range of 50% to 60%

 

 

 

Manual dry cool

16°C~32°C

40%~70

operation

 

 

 

 

 

-10

-15

24

---

---

18

 

– 17 –

 

Page 17
Image 17
Hitachi RAS-SX10HAK / RAC-SX10HAK instruction manual 40 %~70 %, 10C~32C, 16C~32C, Setting Range of AUTO/MANUAL Operation