Hitachi RAS-SX10HAK / RAC-SX10HAK, RAS-SX13HAK / RAC-SX13HAK Mold Monitor Operation, English

Models: RAS-SX10HAK / RAC-SX10HAK RAS-SX13HAK / RAC-SX13HAK

1 96
Download 96 pages 56.33 Kb
Page 23
Image 23

MOLD MONITOR OPERATION

The air conditioner detects indoor temperature and humidity. Once the temperature and humidity reaches to a level conductive to mold growth, the dehumidifying and stainless plasma air purifying operations automatically start.

1

Press the

(FUNCTION SELECTOR) button until

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MOLD MONITOR) blinks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

While

(MOLD MONITOR) is blinking, point the remote controller

towards the unit and press the

 

(ON/OFF) button.

 

 

Preset the mold monitor operation.

During the mold monitor operation, (ON/OFF) and (MONITOR)

indicators on the indoor unit turns on.

Press the (FUNCTION SELECTOR) button again until

(MOLD MONITOR) blinks.

 

While

(MOLD MONITOR) is blinking, point the remote controller

CANCEL towards the unit and press the

(ON/OFF) button.

A short beep sounds and (MOLD MONITOR) indicator turns off on the remote controller.

The (MONITOR) indicator on the indoor unit turns off.

Mold monitoring operation is a preset function. Even if mold monitoring mode is preset, the actual operation will be performed only when the detected temperature and humidity has reached the level conducive to mold growth.

The setting of mold monitoring mode is valid for 2 weeks from the last remote control operation.

(If any remote control operation is performed while (MOLD MONITOR) is set, the preset mold monitoring mode is valid for 2 weeks from such remote control operation.)

Once the above mentioned 2 weeks have elapsed, the (MONITOR) indicator on the indoor unit turns off.

(However, (MOLD MONITOR) indication on the remote controller remains on. If the (MONITOR) indicator on the indoor unit is off, please reset or cancel the mold monitoring mode.)

When mold monitoring mode is set, the fan operation is performed for approximately 3 minutes once every approximately 20 minutes and the room temperature and humidity are detected.

(The movable panel and horizontal air deflector remain closed when temperature and humidity are detected.)

In the first cycle of mold monitoring operation, dehumidifying operation is performed for 4 hours consecutively if the detected temperature and humidity are 10°C and more and 70% and more, respectively. From the second cycle onwards, dehumidifying operation is performed if the detected temperature and humidity reach the above mentioned level and will stop once the humidity has gone down.

For the duration of 20 minutes after mold monitoring operation temporarily stops, the mold monitoring operation is not performed immediately even if mold monitoring mode remains set and the humidity exceeds 70%.

There is no function to remove mold that has grown.

ENGLISH

– 23 –

Page 23
Image 23
Hitachi RAS-SX10HAK / RAC-SX10HAK, RAS-SX13HAK / RAC-SX13HAK instruction manual Mold Monitor Operation, English