DYNAMIC AIR DEFLECTION FUNCTION (TRACING/EVASION)

The infrared sensor can detect the position of people and automatically change the airflow direction.

1

Press the

AUTO AIR DEFLECTION button to switch the air deflection

mode.

 

 

Example: Heating

 

 

 

 

 

 

Pressing the DYNAMIC

Operation Description

 

 

 

 

 

 

AIR DEFLECTION

 

 

button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

·(Tracing) Adjusts the airflow direction

 

 

 

 

 

 

 

 

 

 

automatically to send the air flow to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the location of the person.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

·(Tracing) Adjusts the airflow direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

automatically to keep the air flow away

 

 

 

 

 

 

 

from the location of the person.

 

 

 

 

 

 

 

 

 

 

 

 

Release the

·Return to the setting prior to the dynamic

 

 

 

 

 

 

 

 

 

Dynamic Air

air deflection mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deflection button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

·After the dynamic air deflection mode is set, the sensor usually works once every 15 seconds to 3 minutes to detect the position of the person and adjusts the airflow direction accordingly.

(The airflow direction does not change with the movement of human body immediately.)

·If the dynamic air deflection mode fails to achieve the desired effect, adjust the airflow direction manually.

·When the machine works in cooling, dehumidifying, or dry cool operation after the dynamic air deflection is set, if the indoor humidity/temperature is very high, the left/right/upper/lower air deflectors may change their angles to prevent drop of condensed water. After the temperature falls, the air conditioner returns to the dynamic air deflection status.

How to change the detection speed of the sensor of the dynamic air deflection (tracing/evasion) function:

·There are 2 detection speeds: “Standard” (by intervals of 15"–3') and “Slow” (by intervals of 1'–10'). ·The remote controller is set to the standard speed by default.

·When the detection speed of the sensor is too high, set the detection speed to “Slow”

(when people and pets in the room behave frequently, resulting in frequent changes to the airflow direction).

Set the detection speed of the sensor to “Slow”.

1After the running stops, hold down for more than 5 seconds while pressing and holding. ·At this time, the air conditioner beeps for signal receiving.

·Return to the “Standard” mode by repeating the above procedure (until the air conditioner beeps for signal receiving).

In addition to “Standard” and “Slow” modes, you can also fine tune the detection speed of the sensor.

Fine tune the detection speed of the sensor

2 Hold down

after the running stops

3 Select the desire setting.

(Finely tuned within +3 to -3. The indicator turns off 10 seconds later)

4 Press the

(STOP) button

·The settings are saved.

– 20 –

Page 20
Image 20
Hitachi RAS-SX13HAK / RAC-SX13HAK, RAS-SX10HAK / RAC-SX10HAK Dynamic Air Deflection Function Tracing/Evasion