Hitachi RAS-SX10HAK / RAC-SX10HAK Internal Cleaning Operation, STOP While, English

Models: RAS-SX10HAK / RAC-SX10HAK RAS-SX13HAK / RAC-SX13HAK

1 96
Download 96 pages 56.33 Kb
Page 21
Image 21

INTERNAL CLEANING OPERATION

The internal cleaning operation is automatically performed after cooling, dehumidifying or dry cool operation to

control mold growth by configuring the (INTERNAL CLEAN) operation. (There is no mold removing function and disinfecting/sterilizing effect.)

ENGLISH

Press the (FUNCTION SELECTOR) button

1 until (INTERNAL CLEAN) blinks.

While (INTERNAL CLEAN) is blinking, point the remote controller

towards the unit and press the (ON/OFF) button.

2

A short beep sounds and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(INTERNAL CLEAN) indicator turns on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at the remote controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the (FUNCTION SELECTOR) button again until

(INTERNAL CLEAN) blinks.

 

STOP While

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(INTERNAL CLEAN) is blinking, point the remote controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

towards the unit and press the

(ON/OFF) button.

A short beep sounds and (INTERNAL CLEAN) indicator turns off on the remote controller.

Internal cleaning operation is not performed if the duration of cooling, dehumidifying or dry cool operation is too short (below approximately 10 minutes).

If the internal cleaning mode is set, the internal cleaning operation will automatically start when cooling, dehumidifying or dry cool operation is stopped. During internal cleaning, the heating operation and fan operation (with stainless plasma air purifying) are performed to control the mold growth inside the indoor unit.

While (ON TIMER) is set, internal cleaning operation is not performed from 2 hours before the preset time.

Internal cleaning operation is not performed if the air conditioner operation is stopped in any of the following conditions below.

(heating operation, stainless plasma air purifying operation, quick laundry operation and (OFF TIMER) stop under condensation control operation, operation stopped by (SLEEP) button.)