System Programming

Acquisition Menu

Acquisition Menu

The Acquisition mode is only accessible when there is an SD card present (controllers with the Data Logging, or DLC function). It is used to enable or disable the logging of system Events or transmitter information. The information is logged (or recorded) on an SD card. Intervals or conditions must be defined before using this option.

4. Acquisition

10% threshold mode Start Tx logging Start event logging

The first line of the Acquisition screen offers either :

Delay mode:

Allows for delay intervals of 10 to 59 seconds

 

or 1 to 60 minutes.

Threshold mode:

Allows log values to be set according to set

 

variation thresholds (based on last reading) of

 

3% or more, 5% or more or 10% or more of

 

last detected concentration.

If a 3% threshhold is selected, the system will not log a value at 3% but will log a value of 3.1%. Remember that the sampling rate (system refresh rate) may have an impact on logging.

Here is an example of threshold logging. The logs a semi-colon delineated text files.

2005-04-27 11:05:20;1_CO2_ppm;574;-normal-:

2005-04-27 11:06:02;1_CO2_ppm;503;-normal-:

2005-04-27 11:06:15;1_CO2_ppm;562;-normal-:

2005-04-27 11:06:28;1_CO2_ppm;645;-normal-:

2005-04-27 11:06:39;1_CO2_ppm;557;-normal-:

2005-04-27 11:30:45;1_CO2_ppm;715;-normal-: