PRIMUSr 880 Digital Weather Radar System

The target alert mode can be used in the FP mode. With target alert on and the FP mode selected, the target alert armed annunciation (green TGT) is displayed. The RTA searches for a hazardous target from 5 to 55 miles and ±7.5 degrees of dead ahead. No radar targets are displayed. If a hazardous target is detected, the target alert armed annunciation switches to the alert annunciation (amber TGT). This advises the pilot that a hazardous target is in his flightpath and he

should select the WX mode to view it.

NOTE: When displaying checklist, the TGT function is inoperative.

DTST (Test) - The TST position selects the radar test mode. A special test pattern is displayed to verify system operation. The TEST legend is displayed in the mode field. Refer to Section 4,

Normal Operations, for a description of the test pattern.

WARNING

UNLESS THE SYSTEM IS IN FORCED STANDBY, THE TRANSMIT- TER IS ON AND RADIATING X- BAND MICROWAVE ENERGY IN TEST MODE. REFER TO SECTION 6, MAXIMUM PERMISSIBLE EXPOSURE LEVEL (MPEL).

DFSBY (Forced Standby) - FSBY is an automatic, nonselectable radar mode. As an installation option, the indicator can be wired to the weight- on- wheels (WOW) squat switch. When wired, the RTA is in the FSBY mode when the aircraft is on the ground. In FSBY mode, the transmitter and antenna scan are both inhibited, the display memory is erased, and the FSBY legend is displayed in the mode field. When in the FSBY mode, pushing the STAB button 4

times in 3 seconds restores normal operation.

The FSBY mode is a safety feature that inhibits the transmitter on the ground to eliminate the X- Band microwave radiation hazard. Refer to

Section 6, Maximum Permissible Exposure Level (MPEL).

WARNING

FORCED STANDBY MODE MUST BE VERIFIED BY THE OPERA- TOR TO ENSURE SAFETY FOR GROUND PERSONNEL.

In installations with two radar controllers, it is only necessary to override forced standby from one controller.

If either controller is returned to standby mode while weight is on wheels, the system returns to the forced standby mode.

A28- 1146- 102- 00

Operating Controls

 

3-15

Page 30
Image 30
Honeywell 880 manual Maximum Permissible Exposure Level Mpel