PRIMUSr 880 Digital Weather Radar System
NOTES: 1. FC installations with a radar indicator can display stored faults for the current power- on cycle and nine previous cycles. Installations with radar displayed on the electronic flight instrument system (EFIS) do not display stored faults.
2.In FC installation, that use a radar indicator, when the storage memory is full, the indicator fault storage deletes the oldest power- on fault codes to make room for the newest.
3.In EFIS installations, some weather failures are only annunciated with an amber WX.
4.In EFIS installations, with TEXT FAULTS enabled, the fault codes are also presented as part of the FAIL annunciation (e.g., FAIL 13).
Test Mode With TEXT FAULTS Enabled
Upon entering test mode, the most recent fault is displayed, cycling to the oldest fault in the eligible list of faults. Upon reaching the last fault an END OF LIST message is displayed. To recycle through the list again, exit and re- enter TEST mode.